SECCANT Regeneration Dryer - Safe and Low Maintenance Drying of Air and Gases
Technical Data SECCANT
| Model |
Medium |
Nominal working pressure |
Flow rate* at 200 bar/3000 psig |
Inlet temp. |
Atmos. dewpoint |
Connection tube Ø |
Weight |
| SECCANT III |
Air and non aggressive gases |
90-350 bar
1300-5100 psi |
1500 l/min
55 cfm |
5-45 °C
41-113°F |
<-70 °C
<-94°F |
10 mm |
150 kg
330 Ibs |
| SECCANT IIIA ** |
Air and non aggressive gases |
90-350 bar
1300-5100 psi |
1500 l/min
55 cfm |
5-45 °C
41-113°F |
<-70 °C
<-94°F |
10 mm |
180 kg
400 Ibs |
| SECCANT IV |
Air and non aggressive gases |
90-350 bar
1300-5100 psi |
3500 l/min
125 cfm |
5-45 °C
41-113°F |
<-70 °C
<-94°F |
16 mm |
320 kg
700 Ibs |
| SECCANT IVA ** |
Air and non aggressive gases |
90-350 bar
1300-5100 psi |
3500 l/min
125 cfm |
5-45 °C
41-113°F |
<-70 °C
<-94°F |
16 mm |
400 kg
880 Ibs |
* air capacity at 1 bar/14,5 psi absolute and 20 °C/68°F
** version A for breathing air applications according to DIN EN 12021, EN 12021 and other international standards
Interdependence of the rate of flow and operating pressure:
| Operating pressure (min.) |
bar |
90 |
100 |
150 |
200 |
300 |
350 |
| psi |
1300 |
1450 |
2200 |
2900 |
4350 |
5100 |
| Factor |
0,75 |
0,80 |
0,90 |
1,00 |
1,2 |
1,2 |
Example:
Operating pressure: 300 bar/4350 psig, factor according to the table: 1,20
Flow rate* for SECCANT III:
1500 l/min × 1,2 = 1800 l/min
55 cfm × 1,2 = 66 cfm
Regeneration air/gas volume: 5% of total air capacity
Electric supply: 220 V 50 Hz | 110 V 60 Hz | 12 / 24 V DC | Other voltages available on request
Power consumption: 0,02 kW
Residual oil content:: 0,1 mg/m³ / 0,003 mg/m³ for A version (breathing air)
Explosion proof version available on request.
Dimensions:
| Model |
Width
(mm) - (inch) |
Height
(mm) - (inch) |
Depth
(mm) - (inch) |
| SECCANT III |
900 - 35½ |
1100 - 43¼ |
240 - 9½ |
| SECCANT IIIA ** |
1100 - 43¼ |
1100 - 43¼ |
240 - 9½ |
| SECCANT IV |
1400 - 55 |
1280 - 50¼ |
260 - 10¼ |
| SECCANT IVA ** |
1400 - 55 |
1280 - 50¼ |
260 - 10¼ |
|