Products

B-CONTROL, the Electronic Control for Your Compressor System

Available Extension Moduls for B-CONTROL Basic

External Operational Controls

-

External B-CONTROL Display
B-CONTROLfor connection to the Master-Display of the compressor unit with same indication and control functions as the Master-Display.
Incl. connecting cable 25m length.

-
-
-

B-CONTROL Control Panel
B-CONTROL Bedienfeld externExternal Panel consisting of:
- ON/OFF-
   push button with
   compressor signal lamp
- Fault indication lamp
- Emergency-OFF switch
Incl. connecting cable 5m length.

-
-
-
-
-

Emergency-OFF Module
B-CONTROLRequired if cable length between compressor unit and operational controls exceeds 25m up to max. 100m. Other cable length see accessories.

-
-
 
- Supervision
 
- Interconnetion

Interface Module
Extension of the Electronic Compressor Control B-CONTROL Basic for installation of Pressure / Temperature Modules:
Modulschnittstelle

-

 

B-CONTROL Extended
Extension of the Electronic Compressor Control B-CONTROL Basic with external microprocessor and interface for interconnected operation / communi-cation resp. for installation of Pressure / Temperature Modules:
B-CONTROL Extended

-
-
             
Pressure Module   Temperature Module   Interconnected operation (active) / Communication   Interconnected operation (passive)

Interstage pressure measuring with display of the values on the B-CONTROL display. In case of exceeded standard values, the compressor unit is stopped and the source of fault is indicated on the displayt.

Druckmodul
 

Interstage pressure measuring with display of the values on the B-CONTROL display. In case of exceeded standard values, the compressor unit is stopped and the source of fault is indicated on the displayt.

Temperaturmodul
 

Interconnected operation of up to 4 compressor units for pressure controlled basic and peak load operation; automatic change of the constant load amongst the connected compressors.

For the basic load exchange the elapsed time of each compressor unit is interrogated sequentially. The master compressor unit recognizes faulty compressor unit within the interconnection.

Interface module for communication with a CAN-bus compatible process control system.

Bus cable for interconnected operation and connecting cable for pressure sensor see accessories.

 

Compressor units, which are not equipped with compressor control incl. interconnected operation (active), can be operated as interconneted units.

The module interconneted operation (passive) is only required for the master compressor unit.

Connecting cable for interconnected operation and connecting cable for pressure sensor see accessories.

Visualization, special executions and program accommodations for superset control systems upon request.