4 and 5-Stage High Pressure Breathing Air Compressors
Open Designs
 |
| BPII-10-E3 – Electric Motor Drive |
Pressure
up to 6000 psig
up to 414 bar
Charging Rate
35.9 to 145 scfm
1017 to 4106 l/min
Power
30 to 100 hp
22 to 75 kW
Open packages in horizontal or
vertical configurations combine
compressor and air purification
system in a space saving
design.
These compressors set the standard
for larger capacity air requirements.
STANDARD SCOPE OF SUPPLY
BAUER breathing air purification system
BAUER PLC based controller with four line text display
NEMA 4 rated electrical enclosure with UL® listed control panel
Compressor low oil pressure and high temperature safety shutdowns
Emergency stop push button
Automatic condensate drain system with non-corrosive condensate reservoir and integrated float switch.
Automatic “Full” indication and compressor shutdown
Beltguard designed to meet OSHA guidelines
Soft start, isolation contactor, and circuit breaker providing instantaneous short circuit protection
AVAILABLE ACCESSORIES (factory installed)
Purification upgrade
CO monitor
SECURUS (K42V-E3 and K42-E3 only)
Interstage pressure gauges (locally mounted)
Air storage and Containment Fill Stations allow for customization to meet specific requirements
DIMENSIONS L × W × H inches (mm)
VERTICAL 43 × 83 × 72 (1092 × 2108 × 1830)
HORIZONTAL 114 × 82 × 66 (2896 × 2083 × 1676)
WEIGHT pounds (kg)
VERTICAL 1200 – 2800 (544 – 1270)
HORIZONTAL 1200 – 5000 (544 – 2268)
Technical Data
| Model |
Charging rate 1) |
Number
of stages |
Motor |
FAD 2) |
RPM |
Purification
system |
Dimensions inches (mm) |
Weight |
| scfm |
l/min |
hp |
kW |
L |
W |
H |
lbs. (kg) |
| 5000 psig (345 bar) |
| K42V-E3 3) |
42 |
1190 |
4 |
30 |
22 |
35 |
1300 |
P10 |
43 (1092) |
83 (2108) |
72 (1830) |
1200 – 2800
(544 – 1270) |
| K42-E3 3) |
42 |
1190 |
4 |
30 |
22 |
35 |
1300 |
P10 |
43 (1092) |
83 (2108) |
72 (1830) |
| K60V-E3 |
60 |
1700 |
4 |
40 |
30 |
50 |
1350 |
P12 SECURUS |
43 (1092) |
83 (2108) |
72 (1830) |
| K60-E3 |
60 |
1700 |
4 |
40 |
30 |
50 |
1350 |
P12 SECURUS |
114 (2896) |
82 ( 2083) |
66 (1676) |
1200 – 5000
(544 – 2268) |
| K80-E3 |
80.4 |
2277 |
4 |
60 |
45 |
67 |
1225 |
P14 SECURUS |
114 (2896) |
82 ( 2083) |
66 (1676) |
| K145-E3 |
145 |
4106 |
4 |
100 |
75 |
121 |
1125 |
P14 SECURUS |
114 (2896) |
82 ( 2083) |
66 (1676) |
| 6000 psig (414 bar) |
| H35V-E3 |
35.9 |
1017 |
4 |
30 |
22 |
29.8 |
1200 |
P10 SECURUS |
43 (1092) |
83 (2108) |
72 (1830) |
1200 – 2800
(544 – 1270) |
| H35-E3 |
35.9 |
1017 |
4 |
30 |
22 |
29.8 |
1200 |
P10 SECURUS |
114 (2896) |
82 ( 2083) |
66 (1676) |
1200 – 5000
(544 – 2268) |
| H80-E3 |
80.4 |
2277 |
5 |
60 |
45 |
67 |
1180 |
2 × P10 SECURUS |
114 (2896) |
82 ( 2083) |
66 (1676) |
| H96-E3 |
96 |
2718 |
5 |
75 |
56 |
80 |
1100 |
2 × P10 SECURUS |
114 (2896) |
82 ( 2083) |
66 (1676) |
1) Based on recharging an 80 cubic foot tank from 500 to 3000 psig.
2) Compressor capacity referenced to standard inlet conditions.
3) SECURUS electronic moisture monitoring is not standard.
E3 = Three Phase Electric, 230/460 VAC/60 Hz.
Other voltages available on request.
KV / HV = VERTICAL
K / H = HORIZONTAL
Dimensions and weight are approximate and are subject to change.
|