High Pressure Industrial Compressors for Nitrogen and Noble Gases
G-Series
Compressors for Nitrogen and Noble Gases
| Model |
HP |
Drive |
Capacity SCFM (F.G.D.) |
Number
of
Stages |
Nitrogen
GI |
Helium
GR |
Neon
GR |
Argon
GR |
Krypton
GR |
Xenon
GR |
| NITROGEN TO 5000 PSI / ALL OTHER GASES TO 3200 PSI |
| G_100II |
5 |
E1/E3 |
4.7 |
4.2 |
4.3 |
4.3 |
4.3 |
4.3 |
3 |
| G_120II |
7.5 |
E1/E3 |
7 |
6.3 |
6.5 |
6.3 |
6.4 |
6.4 |
3 |
| G_15.1II |
10 |
E1/E3 |
|
10.3 |
10.6 |
10.4 |
10.6 |
10.6 |
4 |
| 15 |
E3 |
|
13.4 |
13.9 |
13.6 |
13.8 |
13.8 |
| G_150II |
15 |
E3 |
17.5 |
|
|
|
|
|
4 |
| G_180II |
20 |
E3 |
221.5 |
|
|
|
|
|
4 |
| G_220 |
25 |
E3 |
28 |
25.1 |
25.9 |
25.3 |
25.7 |
25.7 |
4 |
| 30 |
33 |
29.6 |
30.5 |
29.8 |
30.3 |
30.3 |
| G_23.1 |
40 |
E3 |
|
38.5 |
39.8 |
38.9 |
39.5 |
39.5 |
4 |
| G_23.0 |
40 |
E3 |
48 |
|
|
|
|
|
4 |
| G_250 |
60 |
E3 |
63 |
|
|
|
|
|
4 |
| G_280 |
75 |
E3 |
88 |
|
|
|
|
|
4 |
| 100 |
E3 |
117 |
|
|
|
|
|
| NITROGEN TO 6000 PSI / ALL OTHER GASES TO 5000 PSI |
| G_12.14II |
7.5 |
E1/E3 |
8.5 |
|
|
|
|
|
4 |
| G_15.11II |
10 |
E1/E3 |
11.4 |
|
|
|
|
|
4 |
| 15 |
E3 |
15 |
|
|
|
|
|
| G_18.1II |
20 |
E3 |
20 |
17.9 |
18.5 |
18.1 |
18.4 |
18.4 |
5 |
| G_22.42 |
25 |
E3 |
28 |
|
|
|
|
|
4 |
| 30 |
33 |
|
|
|
|
|
| G_25.9 |
60 |
E3 |
58 |
52.0 |
53.7 |
52.5 |
53.3 |
53.3 |
5 |
| G_25.18 |
75 |
E3 |
79 |
|
|
|
|
|
5 |
Designation for Nitrogen is G I . Designation for Noble Gases is GR.
SCFM = Standard Cubic Feet per Minute. Tolerance on capacity ±5%.
Maximum Inlet Pressure: 1.5 PSIG.
F.G.D. = Free Gas Delivery.
Referenced to atmospheric intake and 80% of
compressor's maximum working pressure.
E1 = 230 / 1 / 60
E3 = 460 / 3 / 60
Standard Scope of Supply for G Series Packages
 |
| GI15.1 II -
Open Vertical |
Bauer continuous-duty rated, aircooled, multi-stage, reciprocating compressor or booster.
Electric motor drive with ODPmotor, v-belt drive with tensioning device and guarding.
Automatic condensate drain system with condensate collector.
Proprietary PLC-based control system with UL Listed electrical panel.
NEMA 4 electrical enclosure.
Automatic start-stop control.
Full-voltage motor starter.
Fused control voltage transformer.
Operator keypad for start, stop, reset.
Backlit LCD display.
Emergency stop pushbutton.
Hourmeter.
Gauge panel.
Low / High inlet pressure switch with gauge.
High temperature switch.
Pressure lubrication with oil filter, switch for low oil pressure fault and gauge.
Final pressure switch.
Solenoid valve at inlet (normally closed).
Buffer tank at inlet.
Inlet filter with threaded inlet connection.
Coalescing separator at outlet.
Sound attenuated enclosure standard on mini Verticus and MAXI Verticus packages. Mini Verticus and MAXI Verticus available without enclosure. Enclosure available for Large Vertical and Large Horizontal packages.
Ambient temperature range: 40 to 113 degrees F.
Warranty: 1 year.

- Shutoff Valve, Customer Supplied
- Pressure Gauge, Customer Supplied
- Threaded Inlet
- Inlet Solenoid Valve
- Inlet Regulator, available
- Inlet Buffer Tank
- Inlet Filter
- Inlet Pressure Gauge
- Inlet Pressure / Vacuum Switch
- Compressor / Booster
- Final Coalescing Separator
- Final Safety Valve
- Oil Removal Filtration, Available
- Check Valve
- Pressure Maintaining Valve
- Final Pressure Switch
- Threaded Outlet
Dimensions for G-Series Packages
mini VERTICUS and MAXI VERTICUS
| Model |
Dimensions
L × W × H |
Weight |
 |
| Inches |
Pounds |
mini Verticus
G100II, G120II, G12.14II |
46 × 32 × 55 |
750 |
MAXI Verticus
G15.1II, G150II, G15.11II, G180II,
G18.1II |
64 × 34 × 66 |
1025 - 1200 |
Available without enclosure. Contact BAUER.
VERTICAL UNITS, 25 - 40 HP
| Model |
Dimensions
L × W × H |
Weight |
 |
| Inches |
Pounds |
| G220, G22.42 |
62 × 42 × 72 |
1500 |
| G23.0, G23.1 |
80 × 42 × 72 |
2200 |
HORIZONTAL UNITS, 50 - 100 HP
| Model |
Dimensions
L × W × H |
Weight |
 |
| Inches |
Pounds |
| G250, G280, G25.9, G25.18 |
114 × 84 × 66 |
4700 - 5700 |
Custom designs available. Contact BAUER.
Dimensions and weights are approximate.
Subject to modification without notice or obligation.
|